top of page

ΠΟΛΥΜΕΤΡΑ ΗΙΟΚΙ

ΠΟΛΥΜΕΤΡΑ ΗΙΟΚΙ

Digital Multi Meter

The 3256 and 3257 models bear the CE mark meaning that they conform to standards such as the IEC61010-1 international safety standard and other EMC-related standards. Moreover, these units are designed with an emphasis on safety. In addition to a shutter mechanism that prevents incorrect test lead connection, the current terminals of the units come equipped with standard fast blow fuses.

In the AC V range, the 3256 can be used to check whether power lines are live. When the sensitivity level is set to 4 and the test head is placed near a live power line, the built-in buzzer sounds and a display indicator lights.

3256 DIGITAL HITESTER

       Features

  • The terminal shutter interlock mechanism exposes only the correct terminals for connection in the currently selected function

  • Wide range, maximum reading 5610 digit

  • High-speed response, bar graph display

  • Conforms with IEC1010

  • Hold-auto function automatically displays maximum voltage or current value and minimum resistance value

Specifications

DC Voltage Range:

420.0 mV to 1000 V, 5 ranges
Best accuracy: ±0.5 % rdg. ±2 dgt

AC Voltage Range:

420.0 mV to 1000 V, 5 ranges
Best accuracy: ±1.2 % rdg. ±3 dgt. , Average rectifier effective value

Frequency Characteristics (AC voltage):

420.0 mV : 50 to 100 Hz, 4.200 to 1000 V : 50 to 500 Hz

Resistance Range:

420 ohm to 42.00 M-ohm, 6 ranges
Best accuracy: ±0.7 % rdg. ±2 dgt

DC Current Range:

42.00 ?A to 10.00 A, 6 ranges
Accuracy: ±1.5 % rdg. ±4 dgt.

AC Current Range:

42.00 ?A to 10.00 A, 6 ranges
Best accuracy: ±2.5 % rdg. ±5 dgt. , Average rectifier effective value

Frequency Characteristics (AC Current):

50 to 500 Hz

Frequency Range:

0.50 Hz to 500.0 kHz, Input level: 800 mV to 1000 V rms,
Accuracy: ±0.02 % rdg. ±1 dgt.

Continuity:

Possible (50 ohm ?30 ohm) or less

Diode Check:

Possible (3.4 V open terminal voltage)

Other Functions:

Hold-auto Function

Auto Power Save:

Possible (Cancel Possible)

Range Switching:

Auto or Manual

Display:

LCD, maximum 4200 dgt. (all mode), maximum 19999 dgt. (Frequency)
Bar graph display: Maximum 42 segments

Sampling Rate:

2.5 times/sec (all mode), 5 times/sec (Frequency), 25 times/sec (Bar graph)

Power Supply:

R03(AAA) ? 2 dry batteries (Continuous use 100 hours)

Dimensions:

76 mm(2.99 in)W x 167 mm(6.57 in)H x 33 mm(1.30 in)D

Weight:

260 g (9.2 oz)

Accessories:

9207-10 TEST LEAD (1), 3256-50 only: 9378 CARRYING CASE

ΠΟΛΥΜΕΤΡΑ ΗΙΟΚΙ

3804-50 DIGITAL HITESTER  

Hioki 3804-50
Multi-function Digital HiTester Multimeter

       9999 count display full scale for voltage range

  • Optional RS-232C package for transferring data to a PC

  • Average rectified RMS indication

  • Maximum, minimum, average value display

  • 4-20 mA measurement value convert to 0-100 % display, for maintaining and servicing industrial meter

 

By adding capacitance measurement to all the basic DMM functions of AC/DC V, AC/DC A, resistance, diode, and continuity testing, you get the convenience of an all-purpose device that easily enables you to analyze the data, record max/min/avg values, display the relative value and even calculate for 4-20mA in terms of percentage level.

Specifications

Model                               3804-50

Maximum Voltage            9999

DisplayResistance          9999

 Capacitance                   9999

 Current                           9999

 DCV Basic Accuracy     ±0.09%

ACV Basic Accuracy       ±1.2%

Bandwidth                       40 to 500 Hz

TRMS/MEANMEANMEAN

Resistance Basic Accuracy  ±0.3%

Hold Function                    Yes

Recording Function           Yes

4-20mA/ %Conversion      Yes 

Communication Function   Send/Receive RS232C USB

Safety CAT III 600V

           CAT II 1000V

ΠΟΛΥΜΕΤΡΑ ΗΙΟΚΙ

3030-10 ANALOG HITESTER

Hioki 3030-10

Analog HiTester Multimeter

Basic tester with improved safety features

  • Protected against transient voltages up to 250 V AC, preventing electric shock accidents before they can happen

  • Drop proof design withstands dropping onto a concrete floor from a height of 1 meter

  • LED check function

  • Temperature measurement support (with optional probes)

  • CE marking

 

Specifications

DC Voltage range

0.3 V (16.7 k-ohm/V), 3/12/30/120/300/600 V (20 k-ohm/V)  Accuracy: ±2.5 % f.s.

AC Voltage range

12 V (9 k-ohm/V) Accuracy: ±4 % f.s. 30/120/300/600 V (9 k-ohm/V)

Accuracy: ±2.5 % f.s. Average rectifier effective value

Resistance range

0 to 3 k-ohm ( center scale 30 ohm), R × 1, R × 10, R × 100, R × 1 k
Accuracy: ±3 % of scale length

DC Current range

60 µA/30 m/300 mA (300 mV internal voltage drop)
Accuracy: ±3 % f.s.

Other functions

Battery check: 0.9 to 1.8 V, load resistance 10 ohm
Temperature: -20 to 150 °C ( 9021-01 Thermister Temperature Probe is necessary, sold separately)

Safety considerations

Complies with EN61010-1:1992+A2:1995, EN61010-2-031:1994, Installation Category III (anticipated transient overvoltage 6000 V), Pollution Degree 2

Power supply

R6P(AA) × 2 batteries

Dimensions, mass

95 mm(3.74 in)W × 141 mm(5.55 in)H × 39 mm(1.54 in)D, 280 g (9.9 oz)

3246-60 PENCILHITESTER  

Pencil-style Pocket DMM for General Electrical Maintenance, Testing and Hobbyists

The 3246-60 is a pencil-style digital multimeter for general electrical maintenance and testing, and includes a brilliant LED at the pen tip for a clear view of the measurement target.

 

 

• Test lead and main unit in a single body
• Overload protection to 600 V at resistance or continuity functions
• LED light brightly illuminates test points

 

Regarding DMM Accuracy
Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the individual catalogs for detailed accuracy information.

Specifications

DC Voltage

419.9 mV to 600 V, 5 ranges, Basic accuracy:

 ±1.3 % rdg. ±4 dgt.

AC Voltage 50 to 500 Hz

4.199 V to 600 V, 4 ranges, Basic accuracy: ±2.3 % rdg. ±8 dgt. (Average rectified)

Resistance

419.9 Ω to 41.99 MΩ, 6 ranges, Basic accuracy: ±2.0 % rdg. ±4 dgt.

Continuity buzzer

Detection level 50 Ω ±40 Ω

Diode check

Judges the right direction only, Open terminal voltage: 3.4 V or less, Testing current: 800 µA or less

Auto power save

Available (cancel selectable)

Display

Digital LCD, max. 4199 digits

Sampling rate

2.5 times/sec

Power supply

Coin type lithium battery (CR2032) ×1, Continuous use: 150 hours (at DC V function), 30 hours (with light turned on for 10 seconds and off for 20 seconds per cycle and in DC V function)

Dimensions and mass

30 mm (1.18 in)W × 182 mm (7.17 in)H × 26.5 mm (1.04 in)D, 80 g (2.8 oz)

Accessories

Instruction manual ×1, Coin type litium battery (CR2032) ×1 (for trial purposes only), Sleeves (Red/ Black each 1)

MADE IN JAPAN

PDF data

PDF data

PDF data

PDF data

kritsa,ΤΕΡΜΑΤΙΚΟΣ ΔΙΑΚΟΠΤΗΣ, ΦΩΤΟΚΥΤΤΑΡΟ, ΕΠΑΓΩΓΙΚΟΣ,ΧΩΤΙΤΙΚΟΣ,ΜΑΓΝΗΤΙΚΟΣ,ΦΛΟΤΕΡ,ΧΕΙΡΙΣΤΗΡΙΑ,ΠΕΡΙΣΤΡΟΦΙΚΟΣ,ΠΟΛΥΜΕΤΡΑ

© 2015 by K.G.KRITSA & CO

  • Wix Facebook page

          ΤΗΛ: 210-5237709 

                    210-5236890

           FAX: 210-5236890

    e-mail:kritzas@otenet.gr    

 

      ΑΓΙΟΥ ΠΑΥΛΟΥ 19 ΜΕΤΑΞΟΥΡΓΕΙΟ, T.K.10438                   ΑΘΗΝΑ

 

 

bottom of page